EDWARDS SIGNALING ADA HOSPITAL HOTEL SIGNALING DEVICES

1-800-843-6036

Click Here to Email Us

   OnLine Order

Supported Browsers IE, SAFARI, CHROME

More Edwards Signaling Solutions

ADA/HOSPITAL SIGNALING DEVICES

edwards 6538-G5 kit for areas where a call for help or an emergency switch is required6538-G5 Call for Assistance "Kit"

PRICE Each - $116.00

Hotel Room Annunciator Kit/Audible and Visual Signals7005-G5 Hotel Room Annunciator "Kit"/Audible & Visual Signals

PRICE Each - $114.00

6538-G5 CALL FOR ASSISTANCE KIT

The Edwards 6538-G5 Call For Assistance system is designed for areas where a call-for-help or an emergency switch is required.  The kit consists of a Cat. No. 6536-G5 horn/strobe for audible and visual signaling, a Cat. No. 6537 emergency pull cord station, and a Cat. No. 592 transformer.  Each component may also be ordered individually. 

Use in health care facilities, public rest-rooms, and handicapped areas.

6536-G5 HORN/STROBE - The Cat. No. 6536-G5 Horn/Strobe is designed for use in a single gang 2" (51mm) x 4" (102) box located over the door.  Each unit contains an audible horn signal which generates an 82 dBA sound pressure level at 10 ft. and a high intensity strobe.

592 TRANSFORMER - The Edwards Cat. No. 592 transformer is used to power the horn/strobe.  It is equipped with a grounding wire and is suitable for installation in both plastic and metal boxes.

6537 PULL CORD STATIONS - The Cat. No. 6537 pull cord station provides emergency call activation and reset.  It has a stainless steel face plate with a DPST switch. 

FEATURES

  • Double pole single throw switch
  • High intensity strobe
  • Neutral white color
  • Fits single gang box

AGENCY APPROVALS

  • Transformer and horn/strobe UL Listed
  • Horn/strobe UL 1638 Listed
  • Meets ADA requirements

SPECIFICATIONS

  • Transformer primary:  120V AC; secondary:  24V AC
  • Horn/strobe current draw:  175 mA at 24V 50/60 Hz and 125 mA at 24V DC
  • Strobe output:  50 cd on-axis

 

 

 

 

7005-G5 HOTEL ROOM ANNUNCIATOR KIT

The Edwards 7005-G5 Hotel Room Annunciator is for use in hotel rooms and other areas designed to accommodate those with audible, visual, or physical impairments.  The kit consists of a Cat. No. 6536-G5 horn/strobe for audible and visual signaling, a Cat. No. 620 push button, a Cat. No. 147-10 mounting plate, and a Cat. No. 592 transformer.  Each component may also be ordered individually.

Use in hotels, health care facilities, public rest-rooms, and handicapped areas.

620 PUSH BUTTON - The Cat. No. 620 push button station provides call activation when installed in the 147-10 mounting plate.  The plate has a stainless steel face.  The switch is momentary.

FEATURES

  • High intensity strobe
  • Neutral white color
  • Fits single gang box

AGENCY APPROVALS

  • Transformer UL Listed and horn/strobe UL Listed
  • Horn/strobe UL 1638 Listed

SPECIFICATIONS

  • Transformer primary:  120V AC; Secondary:  24V AC
  • Horn/strobe current draw:  175 mA at 24V 50/60 Hz; 125mA at 24V DC
  • Strobe output: 50 cd on-axis

Individual Prices

Cat. No. Description Price Each
6536-G5 Horn/Strobe $84.00
592 Transformer for Horn/Strobe $20.00
620 Push Button $5.00
6537 Pull Cord Station $37.00
147-10 Mounting Plate $12.00

 

 

 

 

 

 

 

Call for Assistance Kit meets ada requirements part# 7008B-N5Call for Assistance "Kit" - Meets ADA requirements Part# 7008B-N5

Price Each - $91.00

Mounting Plate Part# 147-10 room for handicappedMounting Plate# 147-10

Price Each - $12.00

7008B-N5 CALL FOR ASSISTANCE KIT

The Edwards 7008B-N5 120 volt Call For Assistance system is designed for areas where a call-for-help device is required.  The kit consists of a Cat. No. 7007B-N5 buzzer/strobe for audible and visual signaling and a Cat. No. 6537 emergency pull cord station for activation.  Each component may also be ordered individually.

Use in health care facilities, public rest-rooms, and handicapped areas.

7007B-N5 BUZZER/STROBE - The Cat. No. 7007B-N5 buzzer/strobe is designed for installation in a single gang 2" (51mm) x 4" (102mm) box located over doors.  Each unit contains an audible signal which generates an 82 dBA sound pressure level at 10 ft. and a high intensity 150 candela strobe. The unit draws 115 mA.

part number 7007b-n5 buzzer strobe, health care facilities, public rest rooms, handicapped areas

Price Each - $77.00


6537 PULL CORD STATION - The Cat. No. 6537 pull cord station provides emergency call activation and reset.  It has a stainless steel face plate with a DPST switch.

6537 pull coard station provides emergency call activation. Use in health care facilities, public rest rooms and handicapped areas

Price  Each - $37.00

FEATURES

  • 120V AC
  • Double pole single throw switch
  • High intensity strobe
  • Neutral white color
  • Fits single gang box

AGENCY APPROVALS

  • UL Listed
  • Meets ADA requirements

SPECIFICATIONS

  • Buzzer/strobe current draw:  115mA
  • Strobe:  150 candela

 

 

 

 

147-10 MOUNTING PLATE

The Edwards Cat. No. 147-10 Mounting Plate when used with the series 620 Push Buttons forms a convenient station that provides emergency call activation.

Designed for single gang mounting.

Used as a switch plate outside hotel rooms accessible to the handicapped. Supplied as part of the 7005G5 Hotel Room Annunciator.

FEATURES

  • Momentary switch push button
  • Stainless steel face plate

6536-G5 HORN STROBE

Edwards 6536-G5 Horn Strobe audible visual signaling device for use in health acare facilities, public rest rooms and hadicapped areas

Price Each  - $84.00

The Edwards 6536-G5 Horn/Strobe is an audible/visual signaling device that may be used in a variety of system configurations including call for assistance applications.  Designed for installation in a single gang 2" (51mm) x 4" (102) box.

Use in health care facilities, public rest-rooms, and handicapped areas.  Supplied as part of the 6538-G5 Call for Assistance Package.

FEATURES

  • High intensity strobe
  • Neutral white color

AGENCY APPROVALS

  • UL 1638 Listed

SPECIFICATIONS

  • Horn:  82 dBa at 10 feet (3.05m)
  • 24V 50/60 Hz or 24V DC
  • Current draw:  175 mA at 24V 50/60 Hz; 125mA at 24V DC
  • Strobe output:  50 cd on-axis

 

 

 

7007b-n5 buzzer strobe ada hospital signaling deviceBuzzer-Strobe # 7007B-N5

Price  Each - $77.00

bed side station provides emergency call activation use in private and semi-private hospital rooms7302 BEDSIDE STATION

See below for prices

BUZZER/STROBE

7007B-N5

The Edwards 7007B-N5 Buzzer/Strobe is an audible/visual signaling device that may be used in a variety of system configurations including call for assistance applications.

Designed for installation in a single gang 2" (51mm) x 4" (102mm) box.

Use in health care facilities, public rest-rooms, and handicapped areas.  Supplied as part of the 7008B-N5 120 Volt Call for Assistance Kit.

FEATURES

  • High intensity strobe
  • Neutral white color

AGENCY APPROVALS

  • UL Listed

SPECIFICATIONS

  • HORN:  82 dBA at 10 feet (3.05m)
  • Strobe: 150 candela
  • 120V AC
  • Current draw: 115mA
BEDSIDE STATIONS

7302 SERIES

The Edwards Bedside Station provides emergency call activation.  Calls are placed by pulling one of the attached 6 foot (1.83m) cords.  Cords are replaceable with a standard nylon cord.

 Designed for either flush or surface mounting.  Unit fits in a standard single-gang electrical box and plaster cover.  For surface mounting, use a Wiremold surface box.  All boxes must have minimum depth of 1 3/4" (44mm).  Boxes and covers not supplied.

Use in private and semi-private hospital rooms.  Use in emergency stations and patient bath and toilet areas, hospitals, public rest-rooms, and handicapped areas.

FEATURES

  • 3 maintained contacts
  • Stainless steel face plate
  • "Emergency" engraved units available

SPECIFICATIONS

  • 3 amps at 125V AC; 0.5 amps at 125V DC
Cat. No. Description Price Each
7302A Double cord

$129.00

7302AE Double cord, face plate engraved "Emergency"

$140.00

 

7035 nurse call annunciators for use in hospital nurse stations medical offices, corridors, treatment rooms7035 - NURSE CALL ANNUNCIATORS

Price Each - $668.00

nurse call annunciators 7042 use for nurse stations7042 - NURSE CALL ANNUNCIATORS

3 Different Models

See Prices Below

7035 NURSE CALL ANNUNCIATORS

AUDIBLE AND VISUAL SIGNALS

The Edwards 7035 Nurse Call Annunciator provides an unmistakable indication when a patient or resident calls.  The bull's-eye lamps are illuminated and an internal buzzer sounds when external contacts are actuated.  The silencing switch on the front of the unit is used to silence the buzzer.  When the switch is in the off position, buzzer operation is prevented.

The annunciator nay be relamped, without tools, from the front of the unit.

For flush mounting, use a standard 3 gang box (not supplied); for surface mounting, use a Wire Mold box (not supplied).

For small audio/visual call and alarm systems.  For use in hospital nurse stations, medical offices, corridors, and treatment rooms.

FEATURES

  • 4 Bull's-eye lamps
  • Provides both visual and audible signals
  • Brushed stainless steel finish

SPECIFICATIONS

  • 24V AC (Use Cat. No. 599 transformer purchased separately).
7042 NURSE CALL ANNUNCIATORS

AUDIBLE AND VISUAL SIGNALS

The Edwards 7042 Nurse Call Annunciator provides easy to read indications.  Partitioned lamp and socket assemblies prevent cross-lighting of the translucent indicator windows.  Each window is individually back lighted.  A gentle tone buzzer, with a silencing switch, provides an audible indication.  When the switch is in the off position, buzzer operation is prevented.

Flush or surface mount units for large audio/visual call and alarm systems.  For use at hospital nurse stations and other centralized locations.  Wall box is sold separately.

FEATURES

  • 12,24 and 50 window sizes
  • Provides both visual and audible signals
  • Gray enamel finish with hinged door

SPECIFICATIONS

  • 24V AC (Use Cat. No. 88-50 or 88-100 transformers).

***7042-50 is discontinued****

 

 

Nurse Call Annunciators Part# 7042*

CAT NO

WALL BOX INDICATORS

DOWN

ACROSS

SIZE NO.

WIDTH

HEIGHT

A B

7042-12

Flush P029566  Surface  P047701-0111            

12

4

3

1

13 1/2" (343mm)

12 1/4" (311mm) 11 1/2"      (292mm)

10 1/4"  (260mm)

7042-24

Flush P029568    Surface  P047701-0112

24

8

3

2

16 1/2"   (419mm)

16 1/2"  (419mm)

14 1/2"  (368mm)

14 1/2"  (386mm)

7042-50

Discontinued

50

10

5

3

19 1/2"      (495mm)

20 1/2"      (521mm)

17 1/2"   (445mm)

18 1/2"  (470mm)

PRICING

Cat. No Description Price Each
7042-12 Nurse Call Annunicator  (12 indicators) $1,300.00
7042-24 Nurse Call Annunicator  (24 indicators) $1,678.00
7042-50 Nurse Call Annunicator  (50 indicators) **Discontinued** Discontinued

 

 

7603 and 7613 wall stations use for patient service in all ambulatory patient areas

7603 & 7613 Wall Stations

See Below for Pricing

7633 series corridor dome stations 7633 Corridor Dome Stations

See Below for Pricing

 

WALL STATIONS

7603 & 7613 SERIES

The Edwards 7603 & 7613 Wall Station provides convenient call activation.  Calls are placed by simply pushing the locking-type push button on the front of the station.  The 7603 has one button.  The 7613 has one button and one white "call placed" lamp.  When a call is made, the lamp on the front of the unit illuminates, thereby assuring the patient that the call has been properly placed.  Models available with face plate engraved "Emergency."

Designed for either flush or surface mounting.  Unit fits in a standard single-gang electrical box and plaster cover.  For surface mounting, use a Wiremold surface box.  All boxes must have a minimum depth of 2 1/4" (57mm).  Boxes and covers not supplied.

Use for patient service and staff convenience in all ambulatory patient areas.  Often used in medical facilities, lavatories, and other areas where pull cords are not required or desired.

FEATURES

  • 7603 has three maintained contacts, one momentary contact
  • 7613 ahs two maintained contacts, one momentary contact
  • Stainless steel faceplate
  • Heavy duty pushbutton
  • "Emergency" engraved units available

SPECIFICATION

  • Depth in wall box: 1 7/8" (48mm)
  • 24V AC/DC
Cat. No. Description Price Each
7603B Locking Type $68.00
7603E Locking Type, Face Plate Engraved "Emergency" $71.00
7613 Locking type $106.00
7613E Locking type, face plate engraved "Emergency" $109.00
CORRIDOR DOME STATIONS

AUDIBLE AND VISUAL SIGNALS, INTERNAL BUZZER

7633 SERIES

The Edwards 7633 Series Corridor Dome Stations are for use with nurse call systems to visually and audibly indicate the placement of room calls.  Stations are available with 2 or 4 lamps; the domes are designed with barriers between the lamps to prevent visual interference of signals.

The 7633 mounts in a standard double gang box with a plaster cover and a minimum depth of 1 3/4" (44mm).  Boxes and plaster covers not supplied.

For use above entrances to rooms equipped with a bedside call station.

FEATURES

  • Available with 2 or 4 lamps
  • Internal buzzer
  • Stainless steel faceplate
  • White dome
Cat No Description Lamps Volts AC Dome Color* Clear Lamp  Repl** VA Per Lamp
7633-2

Duty/Utility with buzzer and buzzer cut-off switch

1 clear, 1 red***

24

White

A

4.3

7633-4 2 clear,    2 red***

24

White

B

4.75

*Dome replacement-P047047-006

**A-509K, G6, 24V AC Candelabra Screw: B-313, T 3 3/4" 28V Min. Bayonet

***Red lamp replacement-24V: P-036350-0001; 120V:         P-008636-0001

PriceEach:  7633-2  - $142.00          7633-4 - $167.00

 

 

 

7641 and 7641r corridor dome stations 7641 & 7641R Series Corridor Dome Stations

See Below for Pricing

7930 and 7930L wall stations use in medical buildings, assisted living facilities, hospital rooms7930 & 7930L Wall Stations

See Below for Pricing

CORRIDOR DOME STATIONS

7641 & 7641R SERIES

The Edwards 7641 & 7641R Series Corridor Dome Stations are for use with nurse call systems to visually indicate teh placement of room calls.  Stations are available with 1, 2 or 4 lamps; the domes, available in white or red, are designed with barriers between the lamps to prevent visual interference of signals.

The 7641 & 7641R mount in a standard single or double gang box with a plaster cover and a minimum depth of 1 1/2" (38mm).  Boxes and plaster covers not supplied.

For use above entrances to rooms equipped with a bedside call station.

FEATURES

  • Available with 1, 2 or 4 lamps
  • Stainless steel faceplate
  • White or red dome

OPTIONS

  • "X-Ray In Use" replacement lenses.  Order 7641-A1 for wall mount orientation.  Order 7641-A2 for ceiling mount orientation.
CAT. NO Volts AC Clear Lamp Repl** VA Per Lamp Price Each    
7641-1G5 24 B 4.75 $58.00    
7641-1N5 120 A 6.0 $61.00    
7641-2G5 24 B 4.75 $72.00    
7641-2N5 120 A 6.0 $75.00    
7641-4G5 24 B 4.75 $96.00    
7641R-1G5 24 B 4.75 $71.00    
7641R-1N5 120 A 6.0 $74.00

 CAT. NO.

DESCRIPTION

7641-1G5 & 7641-1N5 Corridor dome station with 1 white lamp
7641-2G5 & 7641-2N5 Corridor dome station with 2 lamps ( 1 white,  1 red***)
7641-4G5 Corridor dome station with 4 lamps (2 white,  2 red***)
7641R-1G5 & 7641R-1N5 Corridor dome stations with 1 white lamp
*Dome replacement - White: P-047047-0006  Red: P-047047-0008

**A - 6S6 120V AC Candelabra Screw: B-313, T3 3/4" 28V Min Bayonet

***Red lamp replacement - 24V: P-036350-0001; 120V: P-008636-0001

Wall Station & Calling Cord Set Pricing
Cat. No. Description Price Each
7930 Wall Station $79.00
7930L Wall Station $103.00
7675 6 ft. Calling Cord Set (single cord) $124.00
7676 6 ft. Calling Cord Set (double cord) $204.00
7685 15 ft. Calling Cord Set  (single cord) $208.00
7686 15 ft. Calling Cord Set (double cord) $280.00
7615 Calling Cord Security Clamp $11.00

 

 

 

 

 

 

 

WALL STATIONS  7930 & 7930L

The Edwards 7930 & 7930L Wall Stations provide convenient call activation.  Calls are placed by activating a locking button calling cord.  The 7930L has a lamp on the front of the unit which illuminates when a call is made, thereby assuring the patient that the call has been properly placed.  Calls are automatically placed if the calling cord is accidentally pulled from the receptacle.  Calling cord must be ordered separately.

Use in medical buildings, assisted living facilities, and in private and semi-private hospital rooms.

FEATURES

  • Stainless steel face plate
  • May use either single or dual button calling cords

SPECIFICATIONS

  • 24V AC  (Use Cat. No. 88-50 or 88-100 transformer)
  • Contact rating:  2 amps

CALLING CORD SETS 7675, 7676, 7685 & 7686

calling cord sets for use with nurse call bedside stations

The Edwards Calling Cord Sets are for use with Edwards Cat. No. 7930 and 7930L bedside stations.  The cord sets have either one (7675 and 7685) or two (7676 and 7686) dependable positive action buttons to insure easy placement of calls.  The vinyl outer covering provides a durable insulation that will withstand frequent cleaning and hard usage without cracking or fraying.

The security clamp firmly attaches to the bed sheets or pillows in a manner that will not tear or damage them.

For use with nurse call bedside stations.

FEATURES

  • Pendant locking button(s)
  • Single cord sets (7675, 7685)
  • Double cord sets (7676, 7686)
  • 6 ft. (1.83m) cord(s) (7675, 7676)
  • 15 ft. (4.58m) cords (7685, 7686)
  • Security clamp and plug
  • Momentary contact

CALLING CORD SECURITY CLAMP 7615

calling cord security clamp 7615

This security clamp attaches firmly to the bed sheets or pillows in a manner that will not tear or damage them.

This security clamp is for use with Edwards Cat. No, 7675, 7676, 7685 and 7686 calling cord sets.

 

 

 

 

 

Prices are subject to change without notice. Inventory is subject to prior sale. Product design, specifications & construction are subject to change without notice. Pictures are for general representational purposes and may not represent actual product.

Not Responsible for errors in print, verify all data with us or manufacturer. Terms & Conditions of sale apply, for a copy contact us.

Products may be discontinued without notice.

Visit midsouthelectronics.com for more electronic solutions

Visit midsouthglobal.net