Plenum rated nonmetallic flexible raceway protects fiber optic optical wire cable wires cables wiring cabling. Plenum rated premise conduit innerduct by A-D Technologies Arnco dura-line. This plenum rated conduit non-metallic raceway is ideally suited for plenum and riser applications that require plenum rated non metallic flexible innerduct premise conduit pipe tubing. HDPE Corrugated flexible nonmetallic premise conduit raceway plenum rated.

midsouthcable.com midsouth wire and cable company

GENERAL INFORMATION

FireJacket® is ideally suited for use as a nonmetallic flexible raceway for protecting optical fibers in accordance with NEC articles 770 and 800. It has been tested to meet two Underwriters Laboratory requirements, UL-910 and UL-2024.

Also available with Canadian — UL listing (cUL) meeting or exceeding the requirements for FT-6. Please request the Canadian UL listing at the time of quotation and note on the purchase order. This will assure the material is marked appropriately with the cUL designation.

FireJacket® is ideally suited for use as a nonmetallic flexible raceway for protecting optical fibers in accordance with NEC articles 770 and 800. It has been tested to meet two Underwriters Laboratory requirements, UL-910 and UL-2024.

Firejacket®  Plenum Premise Non-Metallic Innerduct raceway

Plenum Rated flexible raceway to protect fiber optic wire cable

Features & Benefits
 
  • Available in white or orange for easy identification.
  • Rugged corrugated design is flexible, light weight yet provides excellent crush resistance.
  • Listed to UL Standards 910 and 2024, ideally suited for plenum and riser applications per NEC articles 770 and 800. 
  • Choose from 4 diameters, 1", 1-1/4", 1-1/2" and 2" to accommodate your specific fiber cable diameter.
  • Sequential footage markings and product identification printed every two feet.
  • Standard lengths range from 250' coils to 5000' reels.
FAST AND EFFICIENT INSTALLATION

The lightweight, flexible design makes it easy to install and maneuver around obstacles that may be encountered in areas requiring plenum. The corrugated wall provides excellent crush resistance for long-term protection while reducing surface contact between the inside wall of the conduit and the cable jacket, helping to lower cable installation friction. FireJacket® is available with 1000# tensile Bull-Line® pull tape pre-installed to help reduce cable installation costs. Other Bull-Line pull strengths are available upon request.
 

1-800-843-6036

Click Here to Email Us

   OnLine Order

Supported Browsers IE, SAFARI, CHROME

More Innerduct & A-D Technologies Products

WEB PRICING

HDPE CORRUGATED PREMISE PLENUM RATED CONDUIT  INNERDUCT ON 1000FT REELS

*Prices are for PLENUM Rated Conduit with 1000# PULL TAPE PREINSTALLED 

1 INCH  @  $2.372 PER FOOT 1.25 INCH  @  $2.709 PER FOOT
1.5 INCH  @   $3.157 PER FOOT 2 INCH  @   $3.403  PER FOOT
Prices are subject to change without notice.

 

STANDARD REEL & COIL LENGTHS
Non-standard lengths, special markings and assemblies and other Bull-Line® strengths can be made available upon request (minimum quantities may apply). Contact your A-D Technologies sales representative regarding your specific requirements.
 



STANDARD REEL & COIL LENGTHS

Non-Standard lengths, special markings and assemblies and other Bull-Line® Pull Tape strengths can be made available upon request (minimum quantities may apply).

 
 Standard Reel Lengths
 
 Size  Nom OD
 
 Nom ID
 
Wt. Per 100-Ft.
 
 Footage Reel
F X W
 
 Total Weight
 
     CR 500 075 N633 1000
 
 0.75"    1.04"   0.80"        10.0#   1,000'   36 x 30
 
      250#
 CR 500 100 N699 1000  1.00"  1.35" 1.11"
 
12.0#
 
 1,000'  48 x 44
 
 270#
 CR 500 100 N699 2500  1.00"  1.35"  1.11"  12.0#  2,500'  56 x 44
 
 580#
 CR 500 100 N699 5000  1.00"  1.35"  1.11"  12.0#  5,000'  72 x 44
 
 915#
 CR 500 125 N699 1000  1.25"  1.60"  1.30"  13.5#  1,000'  48 x 44
 
 285#
 CR 500 125 N699 2500  1.25"  1.60"  1.30"  13.5#  2,500'  56 x 44
 
 620#
 CR 500 125 N699 5000  1.25"  1.60"  1.30"  13.5#  5,000'  72 x 44
 
 990#
 CR 500 150 N699 1000  1.50"  1.90"  1.55"  16.2#  1,000'  72 x 44
 
 475#
 CR 500 150 N699 2500  1.50"  1.90"  1.55"  16.2#  2,500'  78 x 44
 
 730#
 CR 500 200 N699 1000  2.00"  2.38"  2.10"  18.0#  1,000'  72 x 44
 
 495#
 CR 500 200 N699 1500  2.00"  2.38"  2.10"  18.0#  1,500'  78 x 44
 
 595#
               
 Standard Coil Lengths
 
 Size Nom OD
 
Nom ID
 
Wt. Per 100-ft.
 
Footage
 
Reel
F X W
 
 Total Weight
 
 CR 500 100 N699 0250  1.00"  1.35"  1.11" 12.0#
 
 250' 36 x 17
 
30#
 
 CR 500 100 N699 0500  1.00"  1.35"  1.11"  12.0#  500'  39 x 21
 
 60#
 CR 500 125 N699 0250  1.25"  1.60"  1.30"  13.5#  250'  40 x 16
 
 34#
 CR 500 125 N699 0500  1.25"  1.60"  1.30"  13.5#  500'  40 x 25
 
 68#
 CR 500 150 N699 0250  1.50"  1.90"  1.55"  16.2#  250'  40 x 22
 
 41#
 CR 500 150 N699 0500  1.50"  1.90"  1.55"  16.2#  500'  40 x 22
 
 82#
 CR 500 200 N699 0250  2.00"  2.38"  2.10"  18.0#  250'  40 x 30
 
 45#
 CR 500 200 N699 0500  2.00"  2.38"  2.10"  18.0#  500'  45 x 40
 
 90#

 

plenum rated innerduct flexible conduit coupler couplers terminal adapter adapters plenum rated nonmetallic flexible raceway

 

 

 

1-800-843-6036

Click Here to Email Us

   OnLine Order

Supported Browsers IE, SAFARI, CHROME

More Innerduct & A-D Technologies Products

 

 

Inside Plant Premise Specialty Innerduct HDPE Conduit

GeoGuard GeoThermal Pressure Pipe. High Density Polyethylene (HDPE) Service Tubing 3/4"- 2" diameters for geothermal applications.

GeoGuard   Geothermal Pressure Pipe

High Density Polyethylene (HDPE) Service Tubing 3/4"- 2" diameters for geothermal applications.

 

Innerduct UL Riser HDPE Conduit  Riser Rated Corrugated Conduit Innerduct Durathane® is ideally suited for use as a nonmetallic flexible raceway for protecting and organizing optical fibers in riser applications.  A-D Technologies Arnco and Dura-Line. Premise Conduit innderduct for protecting fiber optic wire cable

Durathane® UL Riser Conduit  Riser Rated Corrugated Conduit  Innerduct

Plenum rated nonmetallic flexible raceway protects fiber optic optical wire cable wires cables wiring cabling. Plenum rated premise conduit innerduct by A-D Technologies Arnco dura-line. This plenum rated conduit non-metallic raceway is ideally suited for plenum and riser applications that require plenum rated non metallic flexible innerduct premise conduit pipe tubing.

Firejacket Plenum Premise Conduit Innerduct

Plenum rated nonmetallic raceway

 

 

innerduct conduit lszh Fiber-Guard®/LSZH (Low Smoke Zero Halogen) is designed for installation in transportation tunnels and other areas where it would be desirable to eliminate release of halogen gas by products due to fire. Due to an increasing awareness, LSZH is designed to significantly reduce the toxic and corrosive side effects caused by fire on humans and sensitive electronic equipment in confined spaces. Use as an innerduct, pulled into steel conduit, in cable tray or directly attached to tunnel walls.

Fiber-Guard Low Smoke Zero Halogen LSZH Conduit Innerduct Raceway

 

 

 

 

 

 

Prices are subject to change without notice.  Inventory is subject to prior sale.  Product design, specifications & construction are subject to change without notice. Pictures are for general representational purposes and may not represent actual product. Not Responsible for errors in print, verify all data with us or manufacturer.  Terms & Conditions of sale apply, for a copy contact us.

Products may be discontinued without notice. Other disclaimers may apply. Minimum order quantities may apply.

 

Plenum rated nonmetallic flexible raceway protects fiber optic optical wire cable wires cables wiring cabling. Plenum rated premise conduit innerduct by A-D Technologies Arnco dura-line. This plenum rated conduit non-metallic raceway is ideally suited for plenum and riser applications that require plenum rated non metallic flexible innerduct premise conduit pipe tubing. HDPE Corrugated flexible nonmetallic premise conduit raceway plenum rated.